MSFC_FibrePortHBAStatistics, ROOT\WMI\ms_409

Class | Methods | Properties (2) | Qualifiers (3) | Instances | Namespaces (2)
Samples: VB Script | C# | VB.Net | Search on:Microsoft

Description

This class exposes statistical information associated with a Fibre Channel port. There should be one instance of this class for each port.

MSFC_FibrePortHBAStatistics properties

MSFC_FibrePortHBAStatistics has 2 properties (2 Local)

NameOriginCIMType
HBAStatusMSFC_FibrePortHBAStatistics19 [uint32]
UniquePortIdMSFC_FibrePortHBAStatistics21 [uint64]

Detailed description of MSFC_FibrePortHBAStatistics properties

Local properties (2) of MSFC_FibrePortHBAStatistics class

HBAStatus property
CIMTYPE'uint32'
Description'HBA Status result for the query operation'
Values['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']
HBAStatus property is in 4 classes of ROOT\WMI\ms_409 and in 2 namespaces
UniquePortId property
CIMTYPE'uint64'
Description'Unique identifier for the port. This idenitifer must be unique among all ports on all adapters. The same value for the identifier must be used for the same port in other classes that expose port information'
UniquePortId property is in 2 classes of ROOT\WMI\ms_409 and in 2 namespaces

MSFC_FibrePortHBAStatistics Qualifiers

NameValueToInstanceToSubclassOverridableAmendedLocal
AMENDMENTTrue
Description'This class exposes statistical information associated with a Fibre Channel port. There should be one instance of this class for each port.'
LOCALE1033

MSFC_FibrePortHBAStatistics System properties

NameValueOriginCIMTypeLocalArray
__PATH'\\.\ROOT\WMI\ms_409:MSFC_FibrePortHBAStatistics'___SYSTEM8
__NAMESPACE'ROOT\WMI\ms_409'___SYSTEM8
__SERVER'.'___SYSTEM8
__DERIVATION[]___SYSTEM8
__PROPERTY_COUNT2___SYSTEM3
__RELPATH'MSFC_FibrePortHBAStatistics'___SYSTEM8
__DYNASTY'MSFC_FibrePortHBAStatistics'___SYSTEM8
__SUPERCLASSnull___SYSTEM8
__CLASS'MSFC_FibrePortHBAStatistics'___SYSTEM8
__GENUS1___SYSTEM3