MS_SM_FabricAndDomainManagementMethods, ROOT\WMI\ms_409

Class | Methods (12) | Properties | Qualifiers (3) | Instances | Namespaces (2)
Samples: VB Script | C# | VB.Net | Search on:Microsoft

MS_SM_FabricAndDomainManagementMethods methods

MS_SM_FabricAndDomainManagementMethods has 12 methods (12 Local)

NameOriginReturn
SM_GetRNIDMgmtInfoMS_SM_FabricAndDomainManagementMethods
SM_SendCTPassThruMS_SM_FabricAndDomainManagementMethods
SM_SendECHOMS_SM_FabricAndDomainManagementMethods
SM_SendLIRRMS_SM_FabricAndDomainManagementMethods
SM_SendRLSMS_SM_FabricAndDomainManagementMethods
SM_SendRNIDMS_SM_FabricAndDomainManagementMethods
SM_SendRPLMS_SM_FabricAndDomainManagementMethods
SM_SendRPSMS_SM_FabricAndDomainManagementMethods
SM_SendSMPPassThruMS_SM_FabricAndDomainManagementMethods
SM_SendSRLMS_SM_FabricAndDomainManagementMethods
SM_SendTESTMS_SM_FabricAndDomainManagementMethods
SM_SetRNIDMgmtInfoMS_SM_FabricAndDomainManagementMethods

Detailed description of MS_SM_FabricAndDomainManagementMethods methods

Local methods (12) of MS_SM_FabricAndDomainManagementMethods class

SM_GetRNIDMgmtInfo method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HBAStatusuint320-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
MgmtInfoobject:HBAFC3MgmtInfo1-{'out':True}
SM_GetRNIDMgmtInfo method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendCTPassThru method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'in':True}
InRespBufferMaxSizeuint321-{'in':True}
ReqBufferSizeuint322-{'in':True}
ReqBufferuint83-{'in':True}
HBAStatusuint324-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
TotalRespBufferSizeuint325-{'out':True}
OutRespBufferSizeuint326-{'out':True}
RespBufferuint87-{'out':True}
SM_SendCTPassThru method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendECHO method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'in':True}
DestWWNuint81-{'in':True}
DestFCIDuint322-{'in':True}
InRespBufferMaxSizeuint323-{'in':True}
ReqBufferSizeuint324-{'in':True}
ReqBufferuint85-{'in':True}
HBAStatusuint326-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
OutRespBufferSizeuint327-{'out':True}
RespBufferuint88-{'out':True}
SM_SendECHO method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendLIRR method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
SourceWWNuint80-{'in':True}
DestWWNuint81-{'in':True}
Functionuint82-{'in':True}
Typeuint83-{'in':True}
InRespBufferMaxSizeuint324-{'in':True}
HBAStatusuint325-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
TotalRespBufferSizeuint326-{'out':True}
OutRespBufferSizeuint327-{'out':True}
RespBufferuint88-{'out':True}
SM_SendLIRR method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendRLS method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'in':True}
DestWWNuint81-{'in':True}
InRespBufferMaxSizeuint322-{'in':True}
HBAStatusuint323-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
TotalRespBufferSizeuint324-{'out':True}
OutRespBufferSizeuint325-{'out':True}
RespBufferuint86-{'out':True}
SM_SendRLS method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendRNID method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'in':True}
DestWWNuint81-{'in':True}
DestFCIDuint322-{'in':True}
NodeIdDataFormatuint323-{'in':True}
InRespBufferMaxSizeuint324-{'in':True}
HBAStatusuint325-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
TotalRespBufferSizeuint326-{'out':True}
OutRespBufferSizeuint327-{'out':True}
RespBufferuint88-{'out':True}
SM_SendRNID method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendRPL method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'in':True}
AgentWWNuint81-{'in':True}
AgentDomainuint322-{'in':True}
PortIndexuint323-{'in':True}
InRespBufferMaxSizeuint324-{'in':True}
HBAStatusuint325-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
TotalRespBufferSizeuint326-{'out':True}
OutRespBufferSizeuint327-{'out':True}
RespBufferuint88-{'out':True}
SM_SendRPL method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendRPS method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'in':True}
AgentWWNuint81-{'in':True}
ObjectWWNuint82-{'in':True}
AgentDomainuint323-{'in':True}
ObjectPortNumberuint324-{'in':True}
InRespBufferMaxSizeuint325-{'in':True}
HBAStatusuint326-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
TotalRespBufferSizeuint327-{'out':True}
OutRespBufferSizeuint328-{'out':True}
RespBufferuint89-{'out':True}
SM_SendRPS method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendSMPPassThru method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'in':True}
DestPortWWNuint81-{'in':True}
DomainPortWWNuint82-{'in':True}
InRespBufferMaxSizeuint323-{'in':True}
ReqBufferSizeuint324-{'in':True}
ReqBufferuint85-{'in':True}
HBAStatusuint326-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
TotalRespBufferSizeuint327-{'out':True}
OutRespBufferSizeuint328-{'out':True}
RespBufferuint89-{'out':True}
SM_SendSMPPassThru method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendSRL method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'in':True}
WWNuint81-{'in':True}
Domainuint322-{'in':True}
InRespBufferMaxSizeuint323-{'in':True}
HBAStatusuint324-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
TotalRespBufferSizeuint325-{'out':True}
OutRespBufferSizeuint326-{'out':True}
RespBufferuint87-{'out':True}
SM_SendSRL method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SendTEST method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'in':True}
DestWWNuint81-{'in':True}
DestFCIDuint322-{'in':True}
ReqBufferSizeuint323-{'in':True}
ReqBufferuint84-{'in':True}
HBAStatusuint325-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
SM_SendTEST method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces
SM_SetRNIDMgmtInfo method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
MgmtInfoobject:HBAFC3MgmtInfo0-{'in':True}
HBAStatusuint321-{'Description':'HBA Status result for the query operation','out':True,'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
SM_SetRNIDMgmtInfo method is in 1 class (MS_SM_FabricAndDomainManagementMethods) of ROOT\WMI\ms_409 and in 2 namespaces

MS_SM_FabricAndDomainManagementMethods Qualifiers

NameValueToInstanceToSubclassOverridableAmendedLocal
AMENDMENTTrue
Description''
LOCALE1033

MS_SM_FabricAndDomainManagementMethods System properties

NameValueOriginCIMTypeLocalArray
__PATH'\\.\ROOT\WMI\ms_409:MS_SM_FabricAndDomainManagementMethods'___SYSTEM8
__NAMESPACE'ROOT\WMI\ms_409'___SYSTEM8
__SERVER'.'___SYSTEM8
__DERIVATION[]___SYSTEM8
__PROPERTY_COUNT0___SYSTEM3
__RELPATH'MS_SM_FabricAndDomainManagementMethods'___SYSTEM8
__DYNASTY'MS_SM_FabricAndDomainManagementMethods'___SYSTEM8
__SUPERCLASSnull___SYSTEM8
__CLASS'MS_SM_FabricAndDomainManagementMethods'___SYSTEM8
__GENUS1___SYSTEM3
comments powered by Disqus
WUtils.com