['Success', 'Not Supported', 'Unspecified Error', 'Timeout', 'Failed', 'Invalid Parameter', 'This command is not supported on x86 running in x64 environment', 'Access Denied', 'An unexpected I/O error has occurred', 'The specified object is managed by the Microsoft Failover Clustering component. The disk must be in cluster maintenance mode and the cluster resource status must be online to perform this operation.', 'The specified cluster size is invalid', 'The specified file system is not supported', 'The volume cannot be quick formatted', 'The number of clusters exceeds 32 bits', 'The specified UDF version is not supported', 'The cluster size must be a multiple of the disk's physical sector size', 'Cannot perform the requested operation when the drive is read only']
Format method is in 1 class (MSFT_Volume) of ROOT\Microsoft\Windows\Storage\ms_409 and in 9 namespaces
{'Description':'Indicates whether the automatic data integrity scanner should scrub files on this volume. True - files on this volume will be scrubbed. False - files on this volume will not be scrubbed.','Out':True}
['Success', 'Not Supported', 'Unspecified Error', 'Timeout', 'Failed', 'Invalid Parameter', 'This command is not supported on x86 running in x64 environment']
Optimize method is in 1 class (MSFT_Volume) of ROOT\Microsoft\Windows\Storage\ms_409 and in 2 namespaces
['Success', 'Not Supported', 'Unspecified Error', 'Timeout', 'Failed', 'Invalid Parameter', 'This command is not supported on x86 running in x64 environment', 'Access denied', 'An unexpected I/O error has occurred', 'The specified file system is not supported', 'Cannot perform the requested operation when the drive is read only', 'The repair failed', 'The scan failed', 'A snapshot error occurred while scanning this drive. You can try again, but if this problem persists, run an offline scan and fix.', 'A scan is already running on this drive. Chkdsk cannot run more than one simultaneous scan on a drive.', 'A snapshot error occurred while scanning this drive. You can try again, but if this problem persists, run an offline scan and fix.', 'A snapshot error occurred while scanning this drive. Run an offline scan and fix.', 'Cannot open drive for direct access', 'Cannot determine the file system of the drive']
{'Description':'Sets whether the automatic data integrity scanner should scrub files on this volume. True - files on this volume will be scrubbed. False - files on this volume will not be scrubbed.','In':True}
['Success', 'Not Supported', 'Unspecified Error', 'Timeout', 'Failed', 'Invalid Parameter', 'This setting may not be changed due to the group policy setting', 'This setting may not be changed due to the global registry setting']