{'Description':'The sensor reading to get information for.'}
Accuracy
sint32
1
-
✓
{'Description':'The accuracy of the reading.'}
Resolution
uint32
2
-
✓
{'Description':'The resolution of the reading.'}
Tolerance
sint32
3
-
✓
{'Description':'The tolerance of the reading.'}
Hysteresis
uint32
4
-
✓
{'Description':'The Hysteresis of the reading.'}
Deprecated
['No Value']
Description
'The use of this method is being deprecated, since Current senor reading can be retrieved through the GetInstance operation. For a non-linear Sensor, the resolution, accuracy, tolerance and hysteresis vary as the current reading moves. This method can be used to get these factors for a given reading. It returns 0 if successful, 1 if unsupported, and any other value if an error occurred. In a subclass, the set of possible return codes could be specified, using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' may also be specified in the subclass as a Values array qualifier.'
'This method resets the values of the thresholds to hardware defaults. This method returns 0 if successful, 1 if unsupported and any other value if an error occurred. In a subclass, the set of possible return codes could be specified, using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' may also be specified in the subclass as a Values array qualifier.'
'The EnableDevice method has been deprecated in lieu of the more general RequestStateChange method that directly overlaps with the functionality provided by this method. Requests that the LogicalDevice be enabled ("Enabled" input parameter = TRUE) or disabled (= FALSE). If successful, the Device's StatusInfo/EnabledState properties should reflect the desired state (enabled/disabled). Note that this method's function overlaps with the RequestedState property. RequestedState was added to the model to maintain a record (i.e., a persisted value) of the last state request. Invoking the EnableDevice method should set the RequestedState property appropriately. The return code should be 0 if the request was successfully executed, 1 if the request is not supported and some other value if an error occurred. In a subclass, the set of possible return codes could be specified, using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' may also be specified in the subclass as a Values array qualifier.'
'The OnlineDevice method has been deprecated in lieu of the more general RequestStateChange method that directly overlaps with the functionality provided by this method. Requests that the LogicalDevice be brought online ("Online" input parameter = TRUE) or taken offline (= FALSE). "Online" indicates that the Device is ready to accept requests, and is operational and fully functioning. In this case, the Device's Availability property would be set to a value of 3 ("Running/Full Power"). "Offline" indicates that a Device is powered up and operational, but not processing functional requests. In an offline state, a Device may be capable of running diagnostics or generating operational alerts. For example, when the "Offline" button is pushed on a Printer, the Device is no longer available to process print jobs, but could be available for diagnostics or maintenance. If this method is successful, the Device's Availability and AdditionalAvailability properties should reflect the updated status. If a failure occurs trying to bring the Device online or offline, it should remain in its current state. IE, the request, if unsuccessful, should not leave the Device in an indeterminate state. When bringing a Device back "Online", from an "Offline" mode, the Device should be restored to its last "Online" state, if at all possible. Only a Device that has an EnabledState/StatusInfo of "Enabled" and has been configured can be brought online or taken offline. OnlineDevice should return 0 if successful, 1 if the request is not supported at all, 2 if the request is not supported due to the current state of the Device, and some other value if any other error occurred. In a subclass, the set of possible return codes could be specified, using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' may also be specified in the subclass as a Values array qualifier. Note that this method's function overlaps with the RequestedState property. RequestedState was added to the model to maintain a record (i.e., a persisted value) of the last state request. Invoking the OnlineDevice method should set the RequestedState property appropriately.'
'The QuiesceDevice method has been deprecated in lieu of the more general RequestStateChange method that directly overlaps with the functionality provided by this method. Requests that the LogicalDevice cleanly cease all current activity ("Quiesce" input parameter = TRUE) or resume activity (= FALSE). For this method to quiesce a Device, that Device should have an Availability (or Additional Availability) of "Running/Full Power" (value=3) and an EnabledStatus/StatusInfo of "Enabled". For example, if quiesced, a Device may then be offlined for diagnostics, or disabled for power off and hot swap. For the method to "unquiesce" a Device, that Device should have an Availability (or AdditionalAvailability) of "Quiesced" (value=21) and an EnabledStatus/StatusInfo of "Enabled". In this case, the Device would be returned to an "Enabled" and "Running/Full Power" status. The method's return code should indicate the success or failure of the quiesce. It should return 0 if successful, 1 if the request is not supported at all, 2 if the request is not supported due to the current state of the Device, and some other value if any other error occurred. In a subclass, the set of possible return codes could be specified, using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' may also be specified in the subclass as a Values array qualifier.'
'Requests that the element's state be changed to the value specified in the RequestedState parameter. When the requested state change takes place, the element's EnabledState and RequestedState will be the same. Invoking the RequestStateChange method multiple times could result in earlier requests being overwritten/lost. If 0 is returned, then the task completed successfully and the use of ConcreteJob was not required. If 4096 (0x1000) is returned, then the task will take some time to complete, ConcreteJob will be created, and its reference returned in the output parameter Job. Any other return code indicates an error condition.'
Values
['Completed with No Error', 'Not Supported', 'Unknown/Unspecified Error', 'Can NOT complete within Timeout Period', 'Failed', 'Invalid Parameter', 'In Use', 'DMTF Reserved', 'Method Parameters Checked - Job Started', 'Invalid State Transition', 'Use of Timeout Parameter Not Supported', 'Busy', 'Method Reserved', 'Vendor Specific']
'Requests a reset of the LogicalDevice. The return value should be 0 if the request was successfully executed, 1 if the request is not supported and some other value if an error occurred. In a subclass, the set of possible return codes could be specified, using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' may also be specified in the subclass as a Values array qualifier.'
'Requests that the Device re-establish its configuration, setup and/or state information from a backing store. This is handled more generally by the ConfigurationData subclass of SettingData. Therefore, this method is deprecated.
The information would have been captured at an earlier time (via the SaveProperties method). This method may not be supported by all Devices. The method should return 0 if successful, 1 if the request is not supported, and some other value if any other error occurred. In a subclass, the set of possible return codes could be specified, using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' may also be specified in the subclass as a Values array qualifier.'
'Requests that the Device capture its current configuration, setup and/or state information in a backing store. This is handled more generally by the ConfigurationData subclass of SettingData. Therefore, this method is deprecated.
The information returned by this method could be used at a later time (via the RestoreProperties method), to return a Device to its present "condition". This method may not be supported by all Devices. The method should return 0 if successful, 1 if the request is not supported, and some other value if any other error occurred. In a subclass, the set of possible return codes could be specified, using a ValueMap qualifier on the method. The strings to which the ValueMap contents are 'translated' may also be specified in the subclass as a Values array qualifier.'
'Sets the power state of the Device. The use of this method has been deprecated. Instead, use the SetPowerState method in the associated PowerManagementService class.'
'Indicates the accuracy of the Sensor for the measured property. Its value is recorded as plus/minus hundredths of a percent. Accuracy, along with Resolution, is used to calculate the actual value of the measured physical property. Accuracy may vary depending on whether the Device is linear over its dynamic range.'
MappingStrings
['MIF.DMTF|Temperature Probe|002.19', 'MIF.DMTF|Electrical Current Probe|001.19', 'MIF.DMTF|Voltage Probe|001.19']
'The base unit of the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is Volts and the UnitModifier is -6, then the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", then the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", then the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier.'
'Indicates the margin built around the thresholds. This margin prevents unnecessary state changes when the Sensor reading may fluctuate very close to its thresholds. This could be due to the Sensor's tolerance/accuracy/resolution or due to environmental factors. Once a threshold is crossed, the state of the Sensor should change. However, the state should not fluctuate between the old and new states unless the Sensor's change in the reading exceeds the hysteresis value. The units for this measurement are determined by BaseUnit*UnitModifier/RateUnit.'
'The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the CurrentReading is between LowerThresholdCritical and Lower ThresholdFatal, then the CurrentState is Critical.'
MappingStrings
['MIF.DMTF|Temperature Probe|002.13', 'MIF.DMTF|Electrical Current Probe|001.13', 'MIF.DMTF|Voltage Probe|001.13']
'The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the CurrentReading is below LowerThresholdFatal, then the Current State is Fatal.'
MappingStrings
['MIF.DMTF|Temperature Probe|002.15', 'MIF.DMTF|Electrical Current Probe|001.15', 'MIF.DMTF|Voltage Probe|001.15']
'The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If Current Reading is between LowerThresholdNonCritical and Upper ThresholdNonCritical, then the Sensor is reporting a normal value. If CurrentReading is between LowerThresholdNonCritical and LowerThresholdCritical, then the CurrentState is NonCritical.'
MappingStrings
['MIF.DMTF|Temperature Probe|002.11', 'MIF.DMTF|Electrical Current Probe|001.11', 'MIF.DMTF|Voltage Probe|001.11']
'Specifies if the units returned by this Sensor are rate units. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). This is true unless this property (RateUnits) has a value different than "None". For example, if BaseUnits is Volts and the UnitModifier is -6, then the units of the values returned are MicroVolts. But, if the RateUnits property is set to a value other than "None", then the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", then the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier. Any implementation of CurrentReading should be qualified with either a Counter or a Gauge qualifier, depending on the characteristics of the sensor being modeled.'
'Resolution indicates the ability of the Sensor to resolve differences in the measured property. The units for this measurement are determined by BaseUnit*UnitModifier/RateUnit.'
MappingStrings
['MIF.DMTF|Temperature Probe|002.17', 'MIF.DMTF|Electrical Current Probe|001.17', 'MIF.DMTF|Voltage Probe|001.17']
'This property is being deprecated in lieu of using the Resolution and Accuracy properties. Indicates the tolerance of the Sensor for the measured property. Tolerance, along with Resolution and Accuracy, is used to calculate the actual value of the measured physical property. Tolerance may vary depending on whether the Device is linear over its dynamic range.'
'The unit multiplier for the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is Volts and the Unit Modifier is -6, then the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", then the units are further qualified as rate units. In the above example, if RateUnits is set to "Per Second", then the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier.'
'The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the CurrentReading is between UpperThresholdCritical and Upper ThresholdFatal, then the CurrentState is Critical.'
MappingStrings
['MIF.DMTF|Temperature Probe|002.14', 'MIF.DMTF|Electrical Current Probe|001.14', 'MIF.DMTF|Voltage Probe|001.14']
'The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the CurrentReading is above UpperThresholdFatal, then the Current State is Fatal.'
MappingStrings
['MIF.DMTF|Temperature Probe|002.16', 'MIF.DMTF|Electrical Current Probe|001.16', 'MIF.DMTF|Voltage Probe|001.16']
'The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the CurrentReading is between LowerThresholdNonCritical and UpperThresholdNonCritical, then the Sensor is reporting a normal value. If the CurrentReading is between UpperThreshold NonCritical and UpperThresholdCritical, then the CurrentState is NonCritical.'
MappingStrings
['MIF.DMTF|Temperature Probe|002.12', 'MIF.DMTF|Electrical Current Probe|001.12', 'MIF.DMTF|Voltage Probe|001.12']
'Additional availability and status of the Device, beyond that specified in the Availability property. The Availability property denotes the primary status and availability of the Device. In some cases, this will not be sufficient to denote the complete status of the Device. In those cases, the AdditionalAvailability property can be used to provide further information. For example, a Device's primary Availability may be "Off line" (value=8), but it may also be in a low power state (AdditonalAvailability value=14), or the Device could be running Diagnostics (AdditionalAvailability value=5, "In Test").'
Values
['Other', 'Unknown', 'Running/Full Power', 'Warning', 'In Test', 'Not Applicable', 'Power Off', 'Off Line', 'Off Duty', 'Degraded', 'Not Installed', 'Install Error', 'Power Save - Unknown', 'Power Save - Low Power Mode', 'Power Save - Standby', 'Power Cycle', 'Power Save - Warning', 'Paused', 'Not Ready', 'Not Configured', 'Quiesced']
'The primary availability and status of the Device. (Additional status information can be specified using the Additional Availability array property.) For example, the Availability property indicates that the Device is running and has full power (value=3), or is in a warning (4), test (5), degraded (10) or power save state (values 13-15 and 17). Regarding the Power Save states, these are defined as follows: Value 13 ("Power Save - Unknown") indicates that the Device is known to be in a power save mode, but its exact status in this mode is unknown; 14 ("Power Save - Low Power Mode") indicates that the Device is in a power save state but still functioning, and may exhibit degraded performance; 15 ("Power Save - Standby") describes that the Device is not functioning but could be brought to full power 'quickly'; and value 17 ("Power Save - Warning") indicates that the Device is in a warning state, though also in a power save mode.'
Values
['Other', 'Unknown', 'Running/Full Power', 'Warning', 'In Test', 'Not Applicable', 'Power Off', 'Off Line', 'Off Duty', 'Degraded', 'Not Installed', 'Install Error', 'Power Save - Unknown', 'Power Save - Low Power Mode', 'Power Save - Standby', 'Power Cycle', 'Power Save - Warning', 'Paused', 'Not Ready', 'Not Configured', 'Quiesced']
'CreationClassName indicates the name of the class or the subclass used in the creation of an instance. When used with the other key properties of this class, this property allows all instances of this class and its subclasses to be uniquely identified.'
'A user-friendly name for the object. This property allows each instance to define a user-friendly name IN ADDITION TO its key properties/identity data, and description information. Note that ManagedSystemElement's Name property is also defined as a user-friendly name. But, it is often subclassed to be a Key. It is not reasonable that the same property can convey both identity and a user friendly name, without inconsistencies. Where Name exists and is not a Key (such as for instances of LogicalDevice), the same information MAY be present in both the Name and ElementName properties.'
'An enumerated value indicating an administrator's default/startup configuration for an element's Enabled State. By default, the element is "Enabled" (value=2).'
'EnabledState is an integer enumeration that indicates the enabled/disabled states of an element. It can also indicate the transitions between these requested states. For example, shutting down (value = 4) and starting (value=10) are transient states between enabled and disabled. The following text briefly summarizes the various enabled/disabled states: Enabled (2) indicates that the element is/could be executing commands, will process any queued commands, and queues new requests. Disabled (3) indicates that the element will not execute commands and will drop any new requests. Shutting Down (4) indicates that the element is in the process of going to a Disabled state. Not Applicable (5) indicates the element doesn't support being enabled/disabled. Enabled but Offline (6) indicates that the element may be completing commands, and will drop any new requests. Test (7) indicates that the element is in a test state. Deferred (8) indicates that the element may be completing commands, but will queue any new requests. Quiesce (9) indicates that the element is enabled but in a restricted mode. The element's behavior is similar to the Enabled state, but it only processes a restricted set of commands. All other requests are queued. Starting (10) indicates that the element is in the process of going to an Enabled state. New requests are queued.'
'ErrorDescription is a free-form string supplying more information about the error recorded in LastErrorCode, and information on any corrective actions that may be taken.'
'Indicates the current health of the element. This attribute expresses the health of this element but not necessarily that of its subcomponents. The possible values are 0 to 30, where 5 means the element is entirely healthy and 30 means the element is completely non-functional. The following continuum is defined: "Non-recoverable Error" (30) - The element has completed failed and recovery is not possible. All functionality provided by this element has been lost. "Critical Failure" (25) - The element is non-functional and recovery MAY NOT be possible. "Major Failure" (20) - The element is failing. It is possible the some or all of the functionality of this component is degraded or not working. "Minor Failure" (15) - All functionality is available but some MAY be degraded. "Degraded/Warning" (10) - The element is in working order and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element may not be operating at optimal performance or it may be reporting recoverable errors. "OK" (5) - The element is fully functional and is operating within normal operational parameters and without error. "Unknown" (0) - The implementation can not report on HealthState at this time. DMTF has reserved the unused portion of the continuum for additional HealthStates in the future.'
'An array of free-form strings providing explanations and details behind the entries in the OtherIdentifyingInfo array. Note, each entry of this array is related to the entry in OtherIdentifyingInfo that is located at the same index.'
'The MaxQuiesceTime property has been deprecated. When evaluating the use of Quiesce, it was determine that this single property is not adequate for describing when a device will automatically exit a quiescent state. In fact, the most likely scenario for a device to exit a quiescent state was determined to be based on the number of outstanding requests queued rather than on a maximum time. This will be re-evaluated and repositioned later. Maximum time in milliseconds, that a Device can run in a "Quiesced" state. A Device's state is defined in its Availability and AdditionalAvailability properties, where "Quiesced" is conveyed by the value 21. What occurs at the end of the time limit is device-specific. The Device may unquiesce, may offline or take other action. A value of 0 indicates that a Device can remain quiesced indefinitely.'
'Indicates the current status(es) of the element. Various operational statuses are defined. Many of the enumeration's values are self- explanatory. However, a few are not and are described in more detail. "Stressed" indicates that the element is functioning, but needs attention. Examples of "Stressed" states are overload, overheated, etc. "Predictive Failure" indicates that an element is functioning nominally but predicting a failure in the near future. "In Service" describes an element being configured, maintained, cleaned, or otherwise administered. "No Contact" indicates that the monitoring system has knowledge of this element, but has never been able to establish communications with it. "Lost Communication" indicates that the ManagedSystem Element is known to exist and has been contacted successfully in the past, but is currently unreachable. "Stopped" and "Aborted" are similar, although the former implies a clean and orderly stop, while the latter implies an abrupt stop where the element's state and configuration may need to be updated. "Dormant" indicates that the element is inactive or quiesced. "Supporting Entity in Error" describes that this element may be "OK" but that another element, on which it is dependent, is in error. An example is a network service or endpoint that cannot function due to lower layer networking problems. "Completed" indicates the element has completed its operation. This value should be combined with either OK, Error, or Degraded so that a client can till if the complete operation passed (Completed with OK), and failure (Completed with Error). Completed with Degraded would imply the operation finished, but did not complete OK or report an error. "Power Mode" indicates the element has additional power model information contained in the Associated PowerManagementService association. OperationalStatus replaces the Status property on ManagedSystemElement to provide a consistent approach to enumerations, to address implementation needs for an array property, and to provide a migration path from today's environment to the future. This change was not made earlier since it required the DEPRECATED qualifier. Due to the widespread use of the existing Status property in management applications, it is strongly RECOMMENDED that providers/instrumentation provide BOTH the Status and OperationalStatus properties. Further, the first value of OperationalStatus SHOULD contain the primary status for the element. When instrumented, Status (since it is single-valued) SHOULD also provide the primary status of the element.'
'A string describing the element's enabled/disabled state when the EnabledState property is set to 1 ("Other"). This property MUST be set to NULL when EnabledState is any value other than 1.'
'OtherIdentifyingInfo captures additional data, beyond DeviceID information, that could be used to identify a LogicalDevice. One example would be to hold the Operating System's user friendly name for the Device in this property.'
'PossibleStates enumerates the string outputs of the Sensor. For example, a "Switch" Sensor may output the states "On", or "Off". Another implementation of the Switch may output the states "Open", and "Close". Another example is a NumericSensor supporting thresholds. This Sensor can report the states like "Normal", "Upper Fatal", "Lower Non-Critical", etc. A NumericSensor that does not publish readings and thresholds, but stores this data internally, can still report its states.'
'An enumerated array describing the power management capabilities of the Device. The use of this property has been deprecated. Instead, the PowerCapabilites property in an associated PowerManagementCapabilities class should be used.'
Values
['Unknown', 'Not Supported', 'Disabled', 'Enabled', 'Power Saving Modes Entered Automatically', 'Power State Settable', 'Power Cycling Supported', 'Timed Power On Supported']
'Boolean indicating that the Device can be power managed. The use of this property has been deprecated. Instead, the existence of an associated PowerManagementCapabilities class (associated using the ElementCapabilities relationhip) indicates that power management is supported.'
'RequestedState is an integer enumeration indicating the last requested or desired state for the element. The actual state of the element is represented by EnabledState. This property is provided to compare the last requested and current enabled/disabled states. Note that when EnabledState is set to 5 ("Not Applicable"), then this property has no meaning. By default, the element's RequestedState is 5 ("No Change"). Refer to the EnabledState's property Description for explanations of the values in the RequestedState enumeration.
It should be noted that there are two new values in RequestedState that build on the statuses of EnabledState. These are "Reboot" (10) and "Reset" (11). The former, Reboot, refers to doing a "Shut Down" and then moving to an "Enabled" state. The latter, Reset, indicates that the element is first "Disabled" and then "Enabled". The distinction between requesting "Shut Down" and "Disabled" should also be noted. The former, Shut Down, requests an orderly transition to the Disabled state, and MAY involve removing power, to completely erase any existing state. The latter, the Disabled state, requests an immediate disabling of the element, such that it will not execute or accept any commands or processing requests.
This property is set as the result of a method invocation (such as Start or StopService on CIM_Service), or may be overridden and defined as WRITEable in a subclass. The method approach is considered superior to a WRITEable property, since it allows an explicit invocation of the operation and the return of a result code.
It is possible that a particular instance of EnabledLogicalElement may not support RequestedStateChange. If this occurs, the value 12 ("Not Applicable") is used.'
'The Type of the Sensor, e.g. Voltage or Temperature Sensor. If the type is set to "Other", then the OtherSensorType Description can be used to further identify the type, or if the Sensor has numeric readings, then the type of the Sensor can be implicitly determined by the Units. A description of the different Sensor types is as follows: A Temperature Sensor measures the environmental temperature. Voltage and Current Sensors measure electrical voltage and current readings. A Tachometer measures speed/revolutions of a Device. For example, a Fan Device can have an associated Tachometer which measures its speed. A Counter is a general purpose Sensor that measures some numerical property of a Device. A Counter value can be cleared, but it never decreases. A Switch Sensor has states like Open/Close, On/Off, or Up/Down. A Lock has states of Locked/Unlocked. Humidity, Smoke Detection and Air Flow Sensors measure the equivalent environmental characteristics. A Presence Sensor detects the presence of a PhysicalElement.'
'A string indicating the current status of the object. Various operational and non-operational statuses are defined. This property is deprecated in lieu of OperationalStatus, which includes the same semantics in its enumeration. This change is made for 3 reasons: 1) Status is more correctly defined as an array. This overcomes the limitation of describing status via a single value, when it is really a multi-valued property (for example, an element may be OK AND Stopped. 2) A MaxLen of 10 is too restrictive and leads to unclear enumerated values. And, 3) The change to a uint16 data type was discussed when CIM V2.0 was defined. However, existing V1.0 implementations used the string property and did not want to modify their code. Therefore, Status was grandfathered into the Schema. Use of the Deprecated qualifier allows the maintenance of the existing property, but also permits an improved definition using OperationalStatus.'
'Strings describing the various OperationalStatus array values. For example, if "Stopping" is the value assigned to OperationalStatus, then this property may contain an explanation as to why an object is being stopped. Note that entries in this array are correlated with those at the same array index in OperationalStatus.'
'The StatusInfo property indicates whether the Logical Device is in an enabled (value = 3), disabled (value = 4) or some other (1) or unknown (2) state. If this property does not apply to the LogicalDevice, the value, 5 ("Not Applicable"), should be used. StatusInfo has been deprecated in lieu of a more clearly named property with additional enumerated values (EnabledState), that is inherited from ManagedSystemElement. If a Device is ("Enabled")(value=3), it has been powered up, and is configured and operational. The Device may or may not be functionally active, depending on whether its Availability (or AdditionalAvailability) indicate that it is ("Running/Full Power")(value=3) or ("Off line") (value=8). In an enabled but offline mode, a Device may be performing out-of-band requests, such as running Diagnostics. If ("Disabled") StatusInfo value=4), a Device can only be "enabled" or powered off. In a personal computer environment, ("Disabled") means that the Device's driver is not available in the stack. In other environments, a Device can be disabled by removing its configuration file. A disabled device is physically present in a System and consuming resources, but can not be communicated with until a load of a driver, a load of a configuration file or some other "enabling" activity has occurred.'
'The date/time when the element's EnabledState last changed. If the state of the element has not changed and this property is populated, then it MUST be set to a 0 interval value. If a state change was requested, but rejected or not yet processed, the property MUST NOT be updated.'