Win32_SoftwareElementCondition, ROOT\CIMV2\ms_409

Class | Methods (1) | Properties (9) | Qualifiers (3) | Instances (999) | Namespaces (2)
Samples: VB Script | C# | VB.Net | Search on:Microsoft

Description

Instances of this class represent conditional checks that must be evaluated to TRUE before their associated Win32_SoftwareElement can be installed.

Win32_SoftwareElementCondition methods

Win32_SoftwareElementCondition has 1 methods (1 Derived)

NameOriginReturn
InvokeCIM_Checkuint32 {'out':True}

Win32_SoftwareElementCondition properties

Win32_SoftwareElementCondition has 9 properties (1 Local, 8 Derived)

NameOriginCIMType
key
CheckID
CIM_Check8 [string]
CheckModeCIM_Check11 [boolean]
ConditionWin32_SoftwareElementCondition8 [string]
DescriptionCIM_Check8 [string]
NameCIM_Check8 [string]
SoftwareElementIDCIM_Check8 [string]
SoftwareElementStateCIM_Check18 [uint16]
TargetOperatingSystemCIM_Check18 [uint16]
VersionCIM_Check8 [string]

Detailed description of Win32_SoftwareElementCondition methods

Derived methods (1) of Win32_SoftwareElementCondition class

Invoke method
Returnuint32 {'out':True}
Description' The invoke method is to evaluate a particular check. The details of how the method evaluates a particular check in a CIM context is described by the non-abstract CIM_Check sub classes. The results of the method are based on the return value. - A 0 (zero) is returned if the condition is satisfied. - A 1 (one) is returned if the method is not supported. - Any other value indicates the condition is not satisfied. '
Invoke method is in 48 classes of ROOT\CIMV2\ms_409 and in 4 namespaces

Detailed description of Win32_SoftwareElementCondition properties

Local properties (1) of Win32_SoftwareElementCondition class

Condition property
CIMTYPE'string'
Description'A conditional statement which evaluates to TRUE or FALSE to determine whether the associated software element should is installed.'
Condition property is in 3 classes of ROOT\CIMV2\ms_409 and in 5 namespaces

Derived properties (8) of Win32_SoftwareElementCondition class

CheckID property
CIMTYPE'string'
Description'An identifier used in conjunction with other keys to uniquely identify the check'
keyTrue
CheckID property is in 23 classes of ROOT\CIMV2\ms_409 and in 2 namespaces
CheckMode property
CIMTYPE'boolean'
Description' The CheckMode property is used to indicate whether the condition is expected to exist or not exist in the environment. When the value is True, the condition is expected to exist (e.g., a file is expected to be on a system) so invoke() is expected to return True. When the value is False, the condition is not expect to exist (e.g., a file is not to be on a system) so invoke is expected to return false '
CheckMode property is in 23 classes of ROOT\CIMV2\ms_409 and in 2 namespaces
Description property
CIMTYPE'string'
Description' A description of the objects.'
Description property is in 329 classes of ROOT\CIMV2\ms_409 and in 142 namespaces
Name property
CIMTYPE'string'
Description'The name used to identify this software element'
Name property is in 306 classes of ROOT\CIMV2\ms_409 and in 142 namespaces
SoftwareElementID property
CIMTYPE'string'
Description' This is an identifier for this software element.'
SoftwareElementID property is in 53 classes of ROOT\CIMV2\ms_409 and in 3 namespaces
SoftwareElementState property
CIMTYPE'uint16'
Description' The software element state of a software element '
Values['Deployable', 'Installable', 'Executable', 'Running']
SoftwareElementState property is in 53 classes of ROOT\CIMV2\ms_409 and in 3 namespaces
TargetOperatingSystem property
CIMTYPE'uint16'
Description' The target operating system of the this software element.'
Values['Unknown', 'Other', 'MACOS', 'ATTUNIX', 'DGUX', 'DECNT', 'Digital Unix', 'OpenVMS', 'HPUX', 'AIX', 'MVS', 'OS400', 'OS/2', 'JavaVM', 'MSDOS', 'WIN3x', 'WIN95', 'WIN98', 'WINNT', 'WINCE', 'NCR3000', 'NetWare', 'OSF', 'DC/OS', 'Reliant UNIX', 'SCO UnixWare', 'SCO OpenServer', 'Sequent', 'IRIX', 'Solaris', 'SunOS', 'U6000', 'ASERIES', 'TandemNSK', 'TandemNT', 'BS2000', 'LINUX', 'Lynx', 'XENIX', 'VM/ESA', 'Interactive UNIX', 'BSDUNIX', 'FreeBSD', 'NetBSD', 'GNU Hurd', 'OS9', 'MACH Kernel', 'Inferno', 'QNX', 'EPOC', 'IxWorks', 'VxWorks', 'MiNT', 'BeOS', 'HP MPE', 'NextStep', 'PalmPilot', 'Rhapsody', 'Windows 2000', 'Dedicated', 'VSE', 'TPF']
TargetOperatingSystem property is in 53 classes of ROOT\CIMV2\ms_409 and in 3 namespaces
Version property
CIMTYPE'string'
Description'Version should be in the form .. or .'
Version property is in 96 classes of ROOT\CIMV2\ms_409 and in 142 namespaces

Win32_SoftwareElementCondition Qualifiers

NameValueToInstanceToSubclassOverridableAmendedLocal
AMENDMENTTrue
Description'Instances of this class represent conditional checks that must be evaluated to TRUE before their associated Win32_SoftwareElement can be installed.'
LOCALE1033

Win32_SoftwareElementCondition System properties

NameValueOriginCIMTypeLocalArray
__PATH'\\.\ROOT\CIMV2\ms_409:Win32_SoftwareElementCondition'___SYSTEM8
__NAMESPACE'ROOT\CIMV2\ms_409'___SYSTEM8
__SERVER'.'___SYSTEM8
__DERIVATION['CIM_Check']___SYSTEM8
__PROPERTY_COUNT9___SYSTEM3
__RELPATH'Win32_SoftwareElementCondition'___SYSTEM8
__DYNASTY'CIM_Check'___SYSTEM8
__SUPERCLASS'CIM_Check'___SYSTEM8
__CLASS'Win32_SoftwareElementCondition'___SYSTEM8
__GENUS1___SYSTEM3

Similar Classes to Win32_SoftwareElementCondition

Number of classes:2
Class nameChildsPropertiesMethodsClass
Instances
Child
Instances
AbstractSingleton
Win32_Condition0111----
Win32_LaunchCondition091----
comments powered by Disqus
WUtils.com