MS_SM_EventControl, ROOT\WMI

Class | Methods (6) | Properties (2) | Qualifiers (6) | Instances | Namespaces (2)
Samples: VB Script | C# | VB.Net | Search on:Microsoft

Description

This class defines the port statistics thresholds that will cause a HBA_EVENT_PORT_STAT_THRESHOLD event to occur

MS_SM_EventControl methods

MS_SM_EventControl has 6 methods (6 Local)

NameOriginReturn
SM_AddLinkMS_SM_EventControl
SM_AddPortMS_SM_EventControl
SM_AddTargetMS_SM_EventControl
SM_RemoveLinkMS_SM_EventControl
SM_RemovePortMS_SM_EventControl
SM_RemoveTargetMS_SM_EventControl

MS_SM_EventControl properties

MS_SM_EventControl has 2 properties (2 Local)

NameOriginCIMType
ActiveMS_SM_EventControl11 [boolean]
key
InstanceName
MS_SM_EventControl8 [string]

Detailed description of MS_SM_EventControl methods

Local methods (6) of MS_SM_EventControl class

SM_AddLink method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HBAStatusuint320-{'Description':'HBA Status result for the query operation','HBAType':'HBA_STATUS','out':True,'ValueMap':['0', '1', '2', '3', '4', '5', '6', '7', '8', '9', '10', '11', '12', '13', '14', '15', '16', '17', '18', '19', '20', '21', '22', '23', '24', '25', '26', '27', '28', '29', '30', '31', '32', '33'],'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
ImplementedTrue
WmiMethodId10
SM_AddLink method is in 1 class (MS_SM_EventControl) of ROOT\WMI and in 1 namespace
SM_AddPort method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
PortWWNuint80-{'HBAType':'HBA_WWN','in':True,'MAX':8}
EventTypeuint321-{'in':True,'ValueMap':['0x100', '0x101', '0x102', '0x103', '0x200', '0x201', '0x202', '0x203', '0x204', '0x205', '0x206', '0x207', '0x208', '0x209', '0x20a', '0x20b', '0x20c', '0x2ff', '0x301', '0x302', '0x351', '0x352', '0x400', '0x401', '0x402', '0x4030x500', '0x501'],'Values':['HBA_EVENT_ADAPTER_UNKNOWN', 'HBA_EVENT_ADAPTER_ADD', 'HBA_EVENT_ADAPTER_REMOVE', 'HBA_EVENT_ADAPTER_CHANGE', 'HBA_EVENT_PORT_UNKNOWN', 'HBA_EVENT_PORT_OFFLINE', 'HBA_EVENT_PORT_ONLINE', 'HBA_EVENT_PORT_NEW_TARGETS', 'HBA_EVENT_PORT_FABRIC', 'HBA_EVENT_PORT_BROADCAST_CHANGE', 'HBA_EVENT_PORT_BROADCAST_D24_0', 'HBA_EVENT_PORT_BROADCAST_D27_4', 'HBA_EVENT_PORT_BROADCAST_SES', 'HBA_EVENT_PORT_BROADCAST_D01_4', 'HBA_EVENT_PORT_BROADCAST_D04_7', 'HBA_EVENT_PORT_BROADCAST_D16_7', 'HBA_EVENT_PORT_BROADCAST_D29_7', 'HBA_EVENT_PORT_ALL', 'HBA_EVENT_PORT_STAT_THRESHOLD', 'HBA_EVENT_PORT_STAT_GROWTH', 'HBA_EVENT_PHY_STAT_THRESHOLD', 'HBA_EVENT_PHY_STAT_GROWTH', 'HBA_EVENT_TARGET_UNKNOWN', 'HBA_EVENT_TARGET_OFFLINE', 'HBA_EVENT_TARGET_ONLINE', 'HBA_EVENT_TARGET_REMOVED', 'HBA_EVENT_LINK_UNKNOWN', 'HBA_EVENT_LINK_INCIDENT']}
HBAStatusuint322-{'Description':'HBA Status result for the query operation','HBAType':'HBA_STATUS','out':True,'ValueMap':['0', '1', '2', '3', '4', '5', '6', '7', '8', '9', '10', '11', '12', '13', '14', '15', '16', '17', '18', '19', '20', '21', '22', '23', '24', '25', '26', '27', '28', '29', '30', '31', '32', '33'],'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
ImplementedTrue
WmiMethodId3
SM_AddPort method is in 1 class (MS_SM_EventControl) of ROOT\WMI and in 1 namespace
SM_AddTarget method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'HBAType':'HBA_WWN','in':True,'MAX':8}
DiscoveredPortWWNuint81-{'HBAType':'HBA_WWN','in':True,'MAX':8}
DomainPortWWNuint82-{'HBAType':'HBA_WWN','in':True,'MAX':8}
AllTargetsuint323-{'in':True}
HBAStatusuint324-{'Description':'HBA Status result for the query operation','HBAType':'HBA_STATUS','out':True,'ValueMap':['0', '1', '2', '3', '4', '5', '6', '7', '8', '9', '10', '11', '12', '13', '14', '15', '16', '17', '18', '19', '20', '21', '22', '23', '24', '25', '26', '27', '28', '29', '30', '31', '32', '33'],'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
ImplementedTrue
WmiMethodId1
SM_AddTarget method is in 1 class (MS_SM_EventControl) of ROOT\WMI and in 1 namespace
SM_RemoveLink method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HBAStatusuint320-{'Description':'HBA Status result for the query operation','HBAType':'HBA_STATUS','out':True,'ValueMap':['0', '1', '2', '3', '4', '5', '6', '7', '8', '9', '10', '11', '12', '13', '14', '15', '16', '17', '18', '19', '20', '21', '22', '23', '24', '25', '26', '27', '28', '29', '30', '31', '32', '33'],'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
ImplementedTrue
WmiMethodId11
SM_RemoveLink method is in 1 class (MS_SM_EventControl) of ROOT\WMI and in 1 namespace
SM_RemovePort method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
PortWWNuint80-{'HBAType':'HBA_WWN','in':True,'MAX':8}
EventTypeuint321-{'in':True,'ValueMap':['0x100', '0x101', '0x102', '0x103', '0x200', '0x201', '0x202', '0x203', '0x204', '0x205', '0x206', '0x207', '0x208', '0x209', '0x20a', '0x20b', '0x20c', '0x2ff', '0x301', '0x302', '0x351', '0x352', '0x400', '0x401', '0x402', '0x4030x500', '0x501'],'Values':['HBA_EVENT_ADAPTER_UNKNOWN', 'HBA_EVENT_ADAPTER_ADD', 'HBA_EVENT_ADAPTER_REMOVE', 'HBA_EVENT_ADAPTER_CHANGE', 'HBA_EVENT_PORT_UNKNOWN', 'HBA_EVENT_PORT_OFFLINE', 'HBA_EVENT_PORT_ONLINE', 'HBA_EVENT_PORT_NEW_TARGETS', 'HBA_EVENT_PORT_FABRIC', 'HBA_EVENT_PORT_BROADCAST_CHANGE', 'HBA_EVENT_PORT_BROADCAST_D24_0', 'HBA_EVENT_PORT_BROADCAST_D27_4', 'HBA_EVENT_PORT_BROADCAST_SES', 'HBA_EVENT_PORT_BROADCAST_D01_4', 'HBA_EVENT_PORT_BROADCAST_D04_7', 'HBA_EVENT_PORT_BROADCAST_D16_7', 'HBA_EVENT_PORT_BROADCAST_D29_7', 'HBA_EVENT_PORT_ALL', 'HBA_EVENT_PORT_STAT_THRESHOLD', 'HBA_EVENT_PORT_STAT_GROWTH', 'HBA_EVENT_PHY_STAT_THRESHOLD', 'HBA_EVENT_PHY_STAT_GROWTH', 'HBA_EVENT_TARGET_UNKNOWN', 'HBA_EVENT_TARGET_OFFLINE', 'HBA_EVENT_TARGET_ONLINE', 'HBA_EVENT_TARGET_REMOVED', 'HBA_EVENT_LINK_UNKNOWN', 'HBA_EVENT_LINK_INCIDENT']}
HBAStatusuint322-{'Description':'HBA Status result for the query operation','HBAType':'HBA_STATUS','out':True,'ValueMap':['0', '1', '2', '3', '4', '5', '6', '7', '8', '9', '10', '11', '12', '13', '14', '15', '16', '17', '18', '19', '20', '21', '22', '23', '24', '25', '26', '27', '28', '29', '30', '31', '32', '33'],'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
ImplementedTrue
WmiMethodId4
SM_RemovePort method is in 1 class (MS_SM_EventControl) of ROOT\WMI and in 1 namespace
SM_RemoveTarget method
Return
Parameters
NameCIMTypeIDINOUTQualifiers
HbaPortWWNuint80-{'HBAType':'HBA_WWN','in':True,'MAX':8}
DiscoveredPortWWNuint81-{'HBAType':'HBA_WWN','in':True,'MAX':8}
DomainPortWWNuint82-{'HBAType':'HBA_WWN','in':True,'MAX':8}
AllTargetsuint323-{'in':True}
HBAStatusuint324-{'Description':'HBA Status result for the query operation','HBAType':'HBA_STATUS','out':True,'ValueMap':['0', '1', '2', '3', '4', '5', '6', '7', '8', '9', '10', '11', '12', '13', '14', '15', '16', '17', '18', '19', '20', '21', '22', '23', '24', '25', '26', '27', '28', '29', '30', '31', '32', '33'],'Values':['Operation was successful ', 'Error ', 'Function not supported.', 'invalid handle ', 'Bad argument ', 'WWN not recognized ', 'Index not recognized ', 'Larger buffer required ', 'Information has changed since the last call to HBA_RefreshInformation ', 'SCSI Check Condition reported', 'Adapter busy or reserved, retry may be effective', 'Request timed out, retry may be effective', 'Referenced HBA has been removed or deactivated', 'The requested ELS was rejected by the local adapter', 'The specified LUN is not provided by the specified adapter', 'An incompatibility has been detected among the library and driver modules', 'Multiple adapters have a matching WWN', 'A persistent binding request included a bad local SCSI bus number', 'A persistent binding request included a bad local SCSI target number', 'A persistent binding request included a bad local SCSI logical unit number', 'A persistent binding set request included a local SCSI ID that was already bound', 'A persistent binding request included a bad or unlocatable FCP Target FCID', 'A persistent binding request included a bad FCP Target Node WWN', 'A persistent binding request included a bad FCP Target Port WWN', 'A persistent binding request included an FCP Logical Unit Number not defined by the identified Target', 'A persistent binding request included an undefined or otherwise in accessible Logical Unit Unique Identifier', 'A persistent binding remove request included a binding which did not match a binding established by the specified port', 'A SCSI command was requested to an Nx_Port that was not a SCSI Target Port', 'A request was made concerning an unsupported FC-4 protocol', 'A request was made to enable unimplemented capabilities for a port', 'SCSI target is busy', 'A call was made to HBA_FreeLibrary when no library was loaded', 'A call was made to HBA_LoadLibrary when a library was already loaded', 'FCID passed into HBA_SendRNIDV2 violates access control rules']}
ImplementedTrue
WmiMethodId2
SM_RemoveTarget method is in 1 class (MS_SM_EventControl) of ROOT\WMI and in 1 namespace

Detailed description of MS_SM_EventControl properties

Local properties (2) of MS_SM_EventControl class

Active property
CIMTYPE'boolean'
Active property is in 378 classes of ROOT\WMI and in 8 namespaces
InstanceName property
CIMTYPE'string'
keyTrue
InstanceName property is in 414 classes of ROOT\WMI and in 9 namespaces

MS_SM_EventControl Qualifiers

NameValueToInstanceToSubclassOverridableAmendedLocal
Description'This class defines the port statistics thresholds that will cause a HBA_EVENT_PORT_STAT_THRESHOLD event to occur'
dynamicTrue
guid'{d6145693-5988-457f-8581-9a0157b58690}'
LOCALE1033
provider'wmiprov'
WMITrue

MS_SM_EventControl System properties

NameValueOriginCIMTypeLocalArray
__PATH'\\.\ROOT\WMI:MS_SM_EventControl'___SYSTEM8
__NAMESPACE'ROOT\WMI'___SYSTEM8
__SERVER'.'___SYSTEM8
__DERIVATION[]___SYSTEM8
__PROPERTY_COUNT2___SYSTEM3
__RELPATH'MS_SM_EventControl'___SYSTEM8
__DYNASTY'MS_SM_EventControl'___SYSTEM8
__SUPERCLASSnull___SYSTEM8
__CLASS'MS_SM_EventControl'___SYSTEM8
__GENUS1___SYSTEM3

Similar Classes to MS_SM_EventControl

Number of classes:1
Class nameChildsPropertiesMethodsClass
Instances
Child
Instances
AbstractSingleton
MSFC_EventControl026----
comments powered by Disqus