|
MSFT_InitiatorPort, ROOT\Microsoft\Windows\Storage
Class
| Methods (1)
| Properties (10)
| Qualifiers (5)
| Instances (1)
| Namespaces (2)
Samples: VB Script
| C#
| VB.Net
| Search on:Microsoft
DescriptionThis class represents a Host Bus Adapter (HBA) an initiator port on the host system.
MSFT_InitiatorPort methodsMSFT_InitiatorPort has 1 methods (1 Local)
MSFT_InitiatorPort propertiesMSFT_InitiatorPort has 10 properties (10 Local)
Detailed description of MSFT_InitiatorPort methodsLocal methods (1) of MSFT_InitiatorPort class▲ SetNodeAddress method |
---|
Return | uint32 {'out':True} |
---|
Parameters | Name | CIMType | ID | IN | OUT | Qualifiers | |
---|
NodeAddress | string | 0 | ✓ | - | {'In':True,'Required':True} | ExtendedStatus | object:MSFT_StorageExtendedStatus | 1 | - | ✓ | {'EmbeddedInstance':'MSFT_StorageExtendedStatus','Out':True} |
|
---|
Description | 'Allows setting the NodeAddress for an iSCSI initiator port by passing an IQN as the NodeAddress string.' |
---|
implemented | True |
---|
ValueMap | ['0', '1', '2', '3', '4', '5'] |
---|
Values | ['Success', 'Not Supported', 'Unspecified Error', 'Timeout', 'Failed', 'Invalid Parameter'] |
---|
SetNodeAddress method is in 1 class (MSFT_InitiatorPort) of ROOT\Microsoft\Windows\Storage and in 2 namespaces |
Detailed description of MSFT_InitiatorPort propertiesLocal properties (10) of MSFT_InitiatorPort class▲ AlternateNodeAddress property |
---|
CIMTYPE | 'string' |
---|
read | True |
---|
AlternateNodeAddress property is in 1 class (MSFT_InitiatorPort) of ROOT\Microsoft\Windows\Storage and in 1 namespace |
▲ AlternatePortAddress property |
---|
CIMTYPE | 'string' |
---|
read | True |
---|
AlternatePortAddress property is in 1 class (MSFT_InitiatorPort) of ROOT\Microsoft\Windows\Storage and in 1 namespace |
▲ InstanceName property |
---|
CIMTYPE | 'string' |
---|
read | True |
---|
InstanceName property is in 1 class (MSFT_InitiatorPort) of ROOT\Microsoft\Windows\Storage and in 9 namespaces |
▲ OperationalStatus property |
---|
CIMTYPE | 'uint16' |
---|
read | True |
---|
ValueMap | ['1', '2', '3', '4', '5', '6', '7', '8'] |
---|
Values | ['Unknown', 'Operational', 'User Offline', 'Bypassed', 'In diagnostics mode', 'Link Down', 'Port Error', 'Loopback'] |
---|
OperationalStatus property is in 10 classes of ROOT\Microsoft\Windows\Storage and in 18 namespaces |
▲ PortType property |
---|
CIMTYPE | 'uint16' |
---|
read | True |
---|
ValueMap | ['1', '2', '3', '5', '6', '7', '8', '9', '10', '20', '21', '30', '31', '32'] |
---|
Values | ['Unknown', 'Other', 'Not present', 'Fabric', 'Public Loop', 'FL Port', 'Fabric Port', 'Fabric expansion port', 'Generic Fabric Port', 'Private Loop', 'Point to Point', 'SAS', 'SATA', 'SAS Expander'] |
---|
PortType property is in 2 classes of ROOT\Microsoft\Windows\Storage and in 12 namespaces |
MSFT_InitiatorPort QualifiersName | Value | ToInstance | ToSubclass | Overridable | Amended | Local |
ClassVersion | '1.0' | ✗ | ✗ | ✓ | ✓ | ✓ |
Description | 'This class represents a Host Bus Adapter (HBA) an initiator port on the host system.' | ✗ | ✓ | ✓ | ✓ | ✓ |
dynamic | True | ✓ | ✗ | ✓ | ✗ | ✓ |
locale | 'MS_409' | ✗ | ✗ | ✓ | ✓ | ✓ |
provider | 'StorageWMI' | ✓ | ✗ | ✓ | ✗ | ✓ |
MSFT_InitiatorPort System propertiesName | Value | Origin | CIMType | Local | Array |
__PATH | '\\.\ROOT\Microsoft\Windows\Storage:MSFT_InitiatorPort' | ___SYSTEM | 8 | ✗ | ✗ |
__NAMESPACE | 'ROOT\Microsoft\Windows\Storage' | ___SYSTEM | 8 | ✗ | ✗ |
__SERVER | '.' | ___SYSTEM | 8 | ✗ | ✗ |
__DERIVATION | [] | ___SYSTEM | 8 | ✗ | ✓ |
__PROPERTY_COUNT | 10 | ___SYSTEM | 3 | ✗ | ✗ |
__RELPATH | 'MSFT_InitiatorPort' | ___SYSTEM | 8 | ✗ | ✗ |
__DYNASTY | 'MSFT_InitiatorPort' | ___SYSTEM | 8 | ✗ | ✗ |
__SUPERCLASS | null | ___SYSTEM | 8 | ✗ | ✗ |
__CLASS | 'MSFT_InitiatorPort' | ___SYSTEM | 8 | ✗ | ✗ |
__GENUS | 1 | ___SYSTEM | 3 | ✗ | ✗ |
Similar Classes to MSFT_InitiatorPortNumber of classes:15
|
|