CIM_SerialInterface, ROOT\CIMV2\ms_409

Class | Methods | Properties (10) | Qualifiers (3) | Instances | Namespaces (2)
Samples: VB Script | C# | VB.Net | Search on:Microsoft

Description

CIM_SerialInterface is a CIM_ControlledBy relationship indicating which devices are accessed through the serial controller and the characteristics of this access.

CIM_SerialInterface properties

CIM_SerialInterface has 10 properties (3 Local, 7 Derived)

NameOriginCIMType
AccessStateCIM_ControlledBy18 [uint16]
AntecedentCIM_Dependency102 [ref:CIM_SerialController]
DependentCIM_Dependency102 [ref:CIM_LogicalDevice]
FlowControlInfoCIM_SerialInterface18 [UINT16]
NegotiatedDataWidthCIM_DeviceConnection19 [uint32]
NegotiatedSpeedCIM_DeviceConnection21 [uint64]
NumberOfHardResetsCIM_ControlledBy19 [uint32]
NumberOfSoftResetsCIM_ControlledBy19 [uint32]
NumberOfStopBitsCIM_SerialInterface18 [UINT16]
ParityInfoCIM_SerialInterface18 [UINT16]

Detailed description of CIM_SerialInterface properties

Local properties (3) of CIM_SerialInterface class

▲ FlowControlInfo property
CIMTYPE'UINT16'
Description'An integer enumeration indicating the flow control (Xon-Xoff and/or RTS/CTS) for transmitted data.'
Values['Unknown', 'Not Supported', 'None', 'XonXoff', 'RTS/CTS', 'Both XonXoff and RTS/CTS']
FlowControlInfo property is in 1 class (CIM_SerialInterface) of ROOT\CIMV2\ms_409 and in 2 namespaces
▲ NumberOfStopBits property
CIMTYPE'UINT16'
Description'Number of stop bits to be transmitted.'
Units'bits'
NumberOfStopBits property is in 1 class (CIM_SerialInterface) of ROOT\CIMV2\ms_409 and in 2 namespaces
▲ ParityInfo property
CIMTYPE'UINT16'
Description'Information on the parity setting for transmitted data. No parity (value=1), even (2) or odd (3) can be specified.'
Values['Unknown', 'None', 'Even', 'Odd']
ParityInfo property is in 1 class (CIM_SerialInterface) of ROOT\CIMV2\ms_409 and in 2 namespaces

Derived properties (7) of CIM_SerialInterface class

▲ AccessState property
CIMTYPE'uint16'
Description'The AccessState property indicates whether the controller is actively commanding or accessing the device (value=1) or not (value=2). Also, the value, "Unknown" (0), can be defined. This information is necessary when a logical device can be commanded by, or accessed through, multiple controllers.'
Values['Unknown', 'Active', 'Inactive']
AccessState property is in 10 classes of ROOT\CIMV2\ms_409 and in 4 namespaces
▲ Antecedent property
CIMTYPE'ref:CIM_SerialController'
Description'The serial controller.'
Antecedent property is in 97 classes of ROOT\CIMV2\ms_409 and in 15 namespaces
▲ Dependent property
CIMTYPE'ref:CIM_LogicalDevice'
Description'The logical device.'
Dependent property is in 97 classes of ROOT\CIMV2\ms_409 and in 15 namespaces
▲ NegotiatedDataWidth property
CIMTYPE'uint32'
Description'When several bus and/or connection data widths are possible, the NegotiatedDataWidth property defines the one in use between the devices. Data width is specified in bits. If data width is not negotiated, or if this information is not available/important to device management, the property should be set to 0.'
Units'bits'
NegotiatedDataWidth property is in 11 classes of ROOT\CIMV2\ms_409 and in 3 namespaces
▲ NegotiatedSpeed property
CIMTYPE'uint64'
Description'When several bus and/or connection speeds are possible, the NegotiatedSpeed property defines the one in use between the devices. Speed is specified in bits per second. If connection or bus speeds are not negotiated, or if this information is not available/important to device management, the property should be set to 0.'
Units'bits per second'
NegotiatedSpeed property is in 11 classes of ROOT\CIMV2\ms_409 and in 3 namespaces
▲ NumberOfHardResets property
CIMTYPE'uint32'
Description'Number of hard resets issued by the controller. A hard reset returns the device to its initialization or 'boot-up' state. All internal device state information and data are lost.'
NumberOfHardResets property is in 10 classes of ROOT\CIMV2\ms_409 and in 3 namespaces
▲ NumberOfSoftResets property
CIMTYPE'uint32'
Description'Number of soft resets issued by the controller. A soft reset does not completely clear current device state and/or data. Exact semantics are dependent on the device, and on the protocols and mechanisms used to communicate to it.'
NumberOfSoftResets property is in 10 classes of ROOT\CIMV2\ms_409 and in 3 namespaces

CIM_SerialInterface Qualifiers

NameValueToInstanceToSubclassOverridableAmendedLocal
AMENDMENTTrue✗✗✓✗✓
Description'CIM_SerialInterface is a CIM_ControlledBy relationship indicating which devices are accessed through the serial controller and the characteristics of this access.'✗✓✓✗✓
LOCALE1033✓✗✓✗✓

CIM_SerialInterface System properties

NameValueOriginCIMTypeLocalArray
__PATH'\\.\ROOT\CIMV2\ms_409:CIM_SerialInterface'___SYSTEM8✗✗
__NAMESPACE'ROOT\CIMV2\ms_409'___SYSTEM8✗✗
__SERVER'.'___SYSTEM8✗✗
__DERIVATION['CIM_ControlledBy', 'CIM_DeviceConnection', 'CIM_Dependency']___SYSTEM8✗✓
__PROPERTY_COUNT10___SYSTEM3✗✗
__RELPATH'CIM_SerialInterface'___SYSTEM8✗✗
__DYNASTY'CIM_Dependency'___SYSTEM8✗✗
__SUPERCLASS'CIM_ControlledBy'___SYSTEM8✗✗
__CLASS'CIM_SerialInterface'___SYSTEM8✗✗
__GENUS1___SYSTEM3✗✗

Similar Classes to CIM_SerialInterface

Number of classes:1
Class nameChildsPropertiesMethodsClass
Instances
Child
Instances
AbstractSingleton
CIM_SCSIInterface090----
comments powered by Disqus
WUtils.com